Streams, mixing and splitting
- Feed streamsComposition, conditions and flow
- ConnectorsJoin streams across flowsheet pages
- Mixer and splitterAdiabatic mixing; split fractions
Coming soon
Steady-state flowsheet simulation and optimization for chemical and process plant design, in the browser: rigorous thermodynamics, columns, reactors and fired heaters, solved unit by unit or all at once.
A first look
Drag equipment onto the canvas, connect it, and solve. Flowsheets span several pages joined by connectors, and every stream shows its conditions on the drawing. Shown here as one example: a crude and vacuum unit with fired heaters. Samples also include methanol synthesis, styrene dehydrogenation, esterification and a cyclohexane plant with recycles and a stabilizer column.

Why ProcessData.Sim
A simulator built around numerical rigor: converged means accurate, balances are checked, and when something is wrong it says so.
The engine reaches thermodynamics through one provider contract, in the style of CAPE-OPEN, for TP, PH, PS and vapor-fraction flashes and phase evaluations. The engine is testable on its own and ready for other property sources.
A small step is not a small error when a loop contracts slowly. ProcessData.Sim estimates the loop's contraction rate, or uses Broyden's own Newton step, so a converged answer is within tolerance of the true solution. An accumulation guard fails any loop with no exit for a component, and names it.
Solve sequential-modular, or equation-oriented: every stream, recycle and specification solved together by Newton on a sparse system, with columns and fired heaters on their own equations. If a simultaneous solve stalls, it falls back to sequential-modular and says why.
Minimize or maximize an objective under constraints. Sequential quadratic programming finds the optimum, writes the decisions back, and prices every active constraint.
Naphtali–Sandholm solves every MESH equation simultaneously; inside-out methods (Boston–Sullivan and Russell) are fast on large columns with many pseudo-components. Both meet the same rigorous tolerance, and if an inside-out solve stalls, Naphtali–Sandholm finishes it.
Every solve checks component, mass and energy balances, and PH flashes are polished so energy closes, not just converges.
Inputs are validated, units are SI throughout, and errors are attributed to the unit or stream concerned. Correlations used outside their data range say so.
An ASP.NET Core API sits under the Angular editor, so simulation can be embedded in engineering workflows and other applications rather than living on a single desktop.
Unit operations
From feed preparation to reaction, separation and heat recovery, on one canvas.
Distillation
Pick the method per column. Both solve the same MESH equations, specifications and results to the same rigorous tolerance; they differ in how they get there.
Simultaneous correction
Newton's method on all stage variables at once, with every property from rigorous thermodynamics. Flows are damped individually, several initial profiles are tried, and warm starts carry the last solution forward. Cubic pseudo-roots and a trivial-solution guard stop a column converging to identical phases.
Inside-out
An inner loop solves the column on simple approximate K-value and enthalpy models, in terms of stage stripping factors. An outer loop updates those models from rigorous thermodynamics until the two agree. With few rigorous property calls, it is fast and forgiving of poor starts on large hydrocarbon columns with many pseudo-components, and Russell's simultaneous inner loop suits side strippers and side draws.
Equipment rating
Results go past stream conditions to how the equipment performs: column hydraulics for trays and packing, fired heater radiant and convection sections, and exchanger profiles.
Reactions
Define kinetic and equilibrium reactions once in a named set and use it in conversion reactors, CSTRs and PFRs, or let a Gibbs reactor find the equilibrium on its own.

Rigorous thermodynamics
Choose the property package that fits the chemistry, from cubic equations of state for hydrocarbons to activity-coefficient models for non-ideal liquids. Phase equilibrium and enthalpy are solved rigorously for every stream, so vapor fractions, duties and compositions stay consistent across the flowsheet.
Property packages
A flowsheet can carry several property packages: every unit uses the main package unless it is given another. Each model comes with a plain-language note on where it applies, changes take effect at the next solve, and model warnings, such as water handled by cubic-EOS screening, are reported in Messages.
| Family | Model | Where it applies |
|---|---|---|
| Equation of state | Peng-Robinson (1976) | Hydrocarbons, light gases and refinery streams. The default. |
| Soave-Redlich-Kwong (1972) | Similar scope to Peng-Robinson, with less accurate liquid densities. | |
| Corresponding states | Lee-Kesler-Plocker | Accurate enthalpies and densities for hydrocarbons and light gases. |
| Grayson-Streed | Hydrogen-rich hydrocarbon systems at refinery conditions, about 255 to 533 K and below 69 bar. | |
| Activity coefficient (γ-φ) | NRTL | Non-ideal condensable liquids at low to moderate pressure, with database binary parameters and an equation-of-state vapor. |
| UNIFAC | Predictive group contribution with an equation-of-state vapor, when no binary parameters are available. |
| Type | Rule | Where it applies |
|---|---|---|
| Classical | van der Waals (VdW1) | Quadratic a, linear b with database k_ij. The standard choice for hydrocarbons and light gases. |
| EOS-GE | Modified Huron-Vidal 2 (MHV2) | With database NRTL, including fitted hydrogen pairs, for polar or strongly non-ideal liquids. |
| MHV1 and Huron-Vidal (HV) | With database NRTL fitted to reproduce the equation of state with its k_ij. | |
| Wong-Sandler (WS) | Matches the second virial coefficient, with a chosen excess model (Original UNIFAC by default). Cannot handle hydrogen. |
| Function | Where it applies |
|---|---|
| Peng-Robinson (1976) | The original kappa(omega) correlation. The standard choice. |
| Peng-Robinson (1978) | Revised kappa for heavy components (acentric factor above 0.491); the same as 1976 below it. |
| Generalized Twu (1995) | From the acentric factor alone: better vapor pressures for heavy and supercritical components. |
| Method | What it does |
|---|---|
| Automatic (stability-guided) | A stability test decides the phases; Boston-Britt and Boston-Fournier inside-out methods solve them, with successive substitution as fallback. The default. |
| Global Gibbs minimum | Solves every candidate route and keeps the lowest Gibbs energy. The most thorough, and several times slower. |
| Successive substitution only | Without the stability test, trying three phases when water is present. For comparison and diagnosis. |
| Boston-Britt only (VLE) | Inside-out VLE alone, which never finds a second liquid. For comparison and diagnosis. |
| Boston-Fournier only (VLLE) | Inside-out VLLE alone, without the stability test. For comparison and diagnosis. |
Used by TP, PH, PS and PU flashes; vapor-fraction flashes always use Automatic.


Design specifications
Each specification varies one number between bounds until its target reaches the value, within a tolerance. All specifications are solved together, and each reports whether it was met and in how many iterations.
Optimization
Set an objective to minimize or maximize and constraints, as expressions over named results, and choose the decisions with their bounds. Evaluate gives the derivatives against each decision; Optimize runs sequential quadratic programming to a local optimum, keeps the constraints, and writes the optimal decisions back so the next solve starts there.

Solver
Solve sequential-modular, where recycle loops are found with Tarjan's algorithm and converged on tear streams (closed loops such as refrigerant circuits included), or equation-oriented, where the whole flowsheet is one sparse system solved by Newton. A structural check names any specification that cannot move its target, and an equation-oriented solve that stalls or would take too long falls back to sequential-modular, with the reason.

| Recycle fraction | Direct substitution | Wegstein | Broyden |
|---|---|---|---|
| 80 % | 74 | 12 | 9 |
| 95 % | 314 | 82 | 10 |
| 99 % | 1,605 | 539 | 12 |
Measured on a flash loop with an ideal-solution test provider, to a relative tolerance of 10−7.
Verified results
Every solve verifies the overall component, mass and energy balances. PH flashes are polished to 0.001 J/mol, because a 1 J/mol miss across every adiabatic unit adds up to a real energy-balance error. ProcessData.Sim reports how tightly the balances close, along with flash statistics and the slowest units, so engineers can trust the numbers and see where the time goes.
From an example crude and vacuum flowsheet with 37 components on Peng-Robinson, in an early build. Solve times depend on the flowsheet.
Petroleum assays, when you need them
When a flowsheet handles crude oil or petroleum fractions, bring each in as an assay and characterize it into pseudo-components the flowsheet can solve. A flowsheet can hold several assays, with pseudo-components kept separate per assay or shared from the blended curve so every assay's cut of the same boiling range has the same properties.
Enter a D86, TBP, D1160 or D2887 distillation curve with its test pressure for vacuum runs, bulk gravity as API or SG, and Watson K set or calculated.
Define light ends by liquid volume or mass percent. They take the front of the curve, and the pseudo-components represent the rest.
Cut the curve automatically or by boiling bands, and pick the correlation for each property: nine for molecular weight, seven for critical temperature and pressure, and three for acentric factor.
Review every pseudo-component's boiling point, gravity, molecular weight, critical temperature and pressure, acentric factor and composition, then save to the flowsheet.

LightCrude example: 30 to 200 °C in 10 cuts, 200 to 370 °C in 12 and 370 to 720 °C in 8, plus 6 light ends.
One set of methods applies to every assay in the flowsheet, so changing one re-characterizes them all.
Themes
Seven display themes, from high-performance grey that lets live alarms stand out, to a dark control room, blueprint, and black-on-white for print. The theme is saved with the flowsheet and never affects results.

Early access
Tell us about the units you model today and we will keep you updated as ProcessData.Sim approaches release.